SQCLR=0, SQMON=0, ACLRM=0, PBUSY=0, PID=00, BSTS=0, SQSET=0
PIPE8 Control Registers
PID | Response PID 0 (00): NAK response 1 (01): BUF response (depends buffer state) 2 (10): STALL response 3 (11): STALL response |
PBUSY | Pipe Busy 0 (0): Pipe n not in use for the transaction 1 (1): Pipe n in use for the transaction |
SQMON | Sequence Toggle Bit Confirmation 0 (0): DATA0 1 (1): DATA1 |
SQSET | Sequence Toggle Bit Set 0 (0): Invalid (writing 0 has no effect) 1 (1): Set the expected value for the next transaction to DATA0 |
SQCLR | Sequence Toggle Bit Clear 0 (0): Invalid (writing 0 has no effect) 1 (1): Clear the expected value for the next transaction to DATA0 |
ACLRM | Auto Buffer Clear Mode 0 (0): Disable 1 (1): Enable (all buffers initialized) |
BSTS | Buffer Status 0 (0): Buffer access disabled 1 (1): Buffer access enabled |